Forensic and structural engineers servingServing VIC, TAS, QLD, SA, NSW and the ACT

Building Code Insights

Notes on Australian Standards and National Construction Code provisions that often cause confusion in practice, from MFS Engineering's forensic structural investigations. Each note names the Standard, its edition and the clauses discussed, with sources.

Browse by Standard

AS 1720Timber structures
AS 2870-2011Residential slabs and footings
AS/NZS 2589:2017Gypsum linings: Application and finishing
Sketch of a brick house under construction with an open book marked NCC as its roof, scaffolding, loose bricks and a tape measure.

All insights

    Sketch of a house beside a tree, with the soil cut away to show the tree's roots spreading under the house.
    AS 2870-2011

    Tree Distance from Buildings

    Safe planting distances for trees near a house under AS 2870-2011, based on soil reactivity and the tree’s mature height.

    22 Nov 2026 · Reading time 2 minutes

    Sketch of a brick wall on the edge of a concrete slab, with the soil cut away to show the footing beneath.
    AS 2870-2011

    Surface Drainage Requirements for Concrete Slabs

    Fall away from the building and slab height above ground under AS 2870-2011 and NCC Housing Provisions 3.3.3, with each state’s NCC edition.

    22 Nov 2026 · Reading time 4 minutes

    Sketch of a tilted house dripping water into a spreading puddle.
    AS 2870-2011

    Abnormal Moisture Conditions

    Abnormal moisture conditions under AS 2870-2011, with examples before, during and after construction: trees, drainage, leaks and watering.

    22 Nov 2026 · Reading time 3 minutes

    Sketch of a house outline with a gauge marked NCC inside, a tree, a downpipe, a stone path and a cut-away of the soil below.
    AS 2870-2011

    Normal Site

    How AS 2870-2011 defines a normal site: Class A, S, M, H1, H2 or E, moisture changes from climate, building, subdivision and normal gardens only.

    22 Nov 2026 · Reading time 2 minutes

    Sketch of a small house on raised garden beds, with a tree behind it and a hose spraying water into the bed beside it.
    AS 2870-2011

    Normal Gardening Conditions

    Gardens near a house under AS 2870-2011 Appendix B: keep drainage and subfloor vents clear, avoid beds against walls, avoid overwatering.

    22 Nov 2026 · Reading time 2 minutes

    Sketch of a garage with its plasterboard ceiling collapsed, the ceiling framing exposed and debris around a parked car.
    AS/NZS 2589:2017

    Installation of Garage Ceilings

    Conventional versus 1/3 fastener spacing for plasterboard ceilings under AS/NZS 2589, and why MFS applies 1/3 spacing to garage ceilings.

    22 Nov 2026 · Reading time 2 minutes

    Sketch of a heavy weight marked KG on a floor supported by open-web joists with timber chords and metal webs.
    AS 1720

    Allowable Deflection Limit for Posi-Strut Flooring

    MFS applies a deflection limit of span/600 to Posi-Strut floors, stricter than the span/300 it generally uses for standard timber floor joists. On a 6 m span that is a maximum of 10 mm. Limits may vary slightly between manufacturers.

    22 Nov 2026 · Reading time 1 minute