In brief

How AS 2870-2011 defines a normal site: Class A, S, M, H1, H2 or E, moisture changes from climate, building, subdivision and normal gardens only.

Sara Khani

Written by

Sara Khani

Senior Forensic Structural Engineer

Standard

AS 2870-2011

Current edition, listed as Pending Revision by Standards Australia. Status checked November 2026

Published

22 November 2026

Revision A · Reading time 2 minutes

What is a ‘Normal’ site in accordance with AS 2870-2011?

Normal sites are those that are:

  • Classified as one of Classes A, S, M, H1, H2 and E
  • Where foundation moisture variations are caused by seasonal and regular climatic effects, effect of the building and subdivision, and normal garden conditions
  • Not subjected to abnormal moisture conditions

What a ‘Normal’ site means in plain English

A ‘Normal’ site typically includes:

  • A site that falls into one of these categories: Class A, S, M, H1, H2, or E.
  • A site where the amount of moisture in the soil changes mostly because of how the building itself affects the soil, the usual weather patterns throughout the year, and normal gardening conditions.
  • A site that has not experienced abnormal moisture conditions.
Sketch of a house in the rain with water running down its downpipes to the ground, and a tree beside the house with a dashed line marked on the ground.
Weather, the house’s own drainage and the garden all change the moisture in the soil of a normal site. Illustration: MFS Engineering.

From our investigations

In our forensic investigations, a house with cracked walls often has several site conditions affecting its footings. These include leaking drains, trees close to the house, and surrounding ground that directs water towards the building. We inspect the building perimeter, review the history of damage and site changes, and compare the cracking pattern with a floor level survey. This helps us assess whether the movement is consistent with seasonal conditions or whether other influences require investigation. A site classification alone does not establish that current conditions remain normal. If cracks keep returning after repairs, doors begin sticking, or floors become noticeably uneven, an engineering assessment can help identify the contributing factors.

References

  • Standards Australia, AS 2870-2011 Residential slabs and footings, Section 2 and Appendix B.
Sketch of a house outline with a gauge marked NCC inside, a tree, a downpipe, a stone path and a cut-away of the soil below.

Unsure how this applies to your property?

Our forensic structural engineers inspect homes in Victoria, Tasmania, Queensland, South Australia, New South Wales and the ACT.

Related service: Preventative Structural Design Engineering

Talk to an engineer

Engineering record

Standard

AS 2870-2011

Residential slabs and footings

Current edition, listed as Pending Revision by Standards Australia. Status checked November 2026.

Clauses discussed

Section 2 and Appendix B

Prepared by

Sara Khani

Senior Forensic Structural Engineer

Revision

Rev A

Published 22 November 2026

Insight ref.

AS2870-04

Quote it when you contact us about this page.

Scope

This page explains the Standard in general terms. It is not an assessment of any particular property.

Revision history

A, 22 November 2026: first issue.

More Building Code Insights

Other Australian Standards and NCC requirements, explained by our engineers.

  • Sketch of a house beside a tree, with the soil cut away to show the tree's roots spreading under the house.
    AS 2870-2011

    Tree Distance from Buildings

    Safe planting distances for trees near a house under AS 2870-2011, based on soil reactivity and the tree’s mature height.

    22 Nov 2026 · Reading time 2 minutes

  • Sketch of a brick wall on the edge of a concrete slab, with the soil cut away to show the footing beneath.
    AS 2870-2011

    Surface Drainage Requirements for Concrete Slabs

    Fall away from the building and slab height above ground under AS 2870-2011 and NCC Housing Provisions 3.3.3, with each state’s NCC edition.

    22 Nov 2026 · Reading time 4 minutes

  • Sketch of a tilted house dripping water into a spreading puddle.
    AS 2870-2011

    Abnormal Moisture Conditions

    Abnormal moisture conditions under AS 2870-2011, with examples before, during and after construction: trees, drainage, leaks and watering.

    22 Nov 2026 · Reading time 3 minutes

View All Insights