What are ‘Normal Gardening Conditions’ according to AS 2870-2011?

According to Appendix B of AS 2870-2011, the development of the gardens should not interfere with the drainage requirements or the subfloor ventilation and weephole drainage systems. Garden beds adjacent to the building should be avoided. Care should be taken to avoid overwatering of gardens close to the building footings.

Sketch of a garden bed built up against a brick wall over its subfloor vents, with water pooling and a hose from a garden tap.
A garden bed against the wall, over the subfloor vents. Illustration: MFS Engineering.
Close-up sketch of water pooling at a subfloor vent in a brick wall, behind dense garden planting.
Water pooling at a subfloor vent behind a garden bed. Illustration: MFS Engineering.

What ‘Normal Gardening Conditions’ mean in plain English

In a nutshell, Appendix B of AS 2870-2011 advises that when setting up gardens, a few key points should be considered:

  • Gardens should not disrupt the drainage systems or subfloor ventilation, which are crucial for maintaining the structural integrity of buildings.
  • Placing garden beds directly adjacent to building walls is generally not recommended.
  • Excessive watering of gardens near building foundations should be avoided to prevent potential damage.

Essentially, it’s important to be mindful of how gardens are positioned and maintained in relation to building structures to ensure long-term satisfactory performance of footings.

Sketch of a two-storey house with paving between its walls and the garden beds, and a hose in one bed.
Garden beds kept away from the walls, with paving between. Illustration: MFS Engineering.

From our investigations

On site, we regularly find garden beds built against external walls, soil covering weepholes or subfloor vents, and irrigation repeatedly wetting the ground beside the footings. These arrangements can look harmless while changing the moisture conditions supporting the house. We check garden levels against the building, the direction of surface drainage, irrigation locations, and whether planting obstructs ventilation or drainage openings. We also compare these conditions with the location of cracking and floor movement. If damage develops beside a garden bed, or continues despite cosmetic repairs, an engineer should assess whether the landscaping is contributing before further repairs or substantial garden alterations are undertaken.

References

  • Standards Australia, AS 2870-2011 Residential slabs and footings, Section 2 and Appendix B.
Sketch of a small house on raised garden beds, with a tree behind it and a hose spraying water into the bed beside it.

Unsure how this applies to your property?

Our forensic structural engineers inspect homes in Victoria, Tasmania, Queensland, South Australia, New South Wales and the ACT.

Related service: Forensic Structural Investigation

Talk to an engineer

Engineering record

Standard

AS 2870-2011

Residential slabs and footings

Current edition, listed as Pending Revision by Standards Australia. Status checked November 2026.

Clauses discussed

Section 2 and Appendix B

Prepared by

Sara Khani

Senior Forensic Structural Engineer

Revision

Rev A

Published 22 November 2026

Insight ref.

AS2870-02

Quote it when you contact us about this page.

Scope

This page explains the Standard in general terms. It is not an assessment of any particular property.

Revision history

A, 22 November 2026: first issue.

More Building Code Insights

Other Australian Standards and NCC requirements, explained by our engineers.

  • Sketch of a house beside a tree, with the soil cut away to show the tree's roots spreading under the house.
    AS 2870-2011

    Tree Distance from Buildings

    Safe planting distances for trees near a house under AS 2870-2011, based on soil reactivity and the tree’s mature height.

    22 Nov 2026 · Reading time 2 minutes

  • Sketch of a brick wall on the edge of a concrete slab, with the soil cut away to show the footing beneath.
    AS 2870-2011

    Surface Drainage Requirements for Concrete Slabs

    Fall away from the building and slab height above ground under AS 2870-2011 and NCC Housing Provisions 3.3.3, with each state’s NCC edition.

    22 Nov 2026 · Reading time 4 minutes

  • Sketch of a tilted house dripping water into a spreading puddle.
    AS 2870-2011

    Abnormal Moisture Conditions

    Abnormal moisture conditions under AS 2870-2011, with examples before, during and after construction: trees, drainage, leaks and watering.

    22 Nov 2026 · Reading time 3 minutes

View All Insights