Forensic and structural engineers servingServing VIC, TAS, QLD, SA, NSW and the ACT

AS 2870-2011Residential slabs and footings

Tree Distance from Buildings

In brief

Safe planting distances for trees near a house under AS 2870-2011, based on soil reactivity and the tree’s mature height.

Sara Khani

Written by

Sara Khani

Senior Forensic Structural Engineer

Standard

AS 2870-2011

Current edition, listed as Pending Revision by Standards Australia. Status checked November 2026

Published

22 November 2026

Revision A · Reading time 2 minutes

When designing landscapes around buildings on reactive soil types, it’s crucial to consider the impact of tree roots to prevent soil drying and subsequent building damage.

Sketch of a tree growing from a block of soil that is dry and deeply cracked around its roots.
Soil dried and cracked around a tree’s roots. Illustration: MFS Engineering.
Sketch of a two-storey brick house with stepped cracks in its walls beside a large tree, one crack shown magnified.
Cracked walls on a house close to a large tree. Illustration: MFS Engineering.

Simplified guide to planting distances based on soil reactivity, according to AS 2870-2011

  • Extremely Reactive Soils (Class E): Plant trees no closer than 1.5 times their mature height from the building.
  • Highly Reactive Soils (Class H1 and H2): Maintain a distance equal to the mature height of the tree.
  • Moderately Reactive Soils (Class M): Trees should be planted at least ¾ of their mature height away from the structure.
  • Multiple Trees or Groups: Increase the recommended distance by 50% to further reduce potential damage.
Sketch of a house and a single tree, with the distance between them marked 1 × the tree's height.
A single tree planted its mature height (1 ×) from the house, the guide for highly reactive soils (Class H1 and H2). Illustration: MFS Engineering.

Additional Landscaping Considerations

  • Soil Testing: Conduct thorough soil analyses to determine the exact reactivity class and tailor your landscaping accordingly.
  • Seasonal Changes: Account for seasonal moisture variations and their impact on soil volume changes near foundations.
  • Species selection: Being native does not by itself make a tree safe near footings; consider the species’ water demand and mature size.
  • Irrigation Practices: Implement smart irrigation systems to maintain consistent soil moisture around the building perimeter.
  • Paving: A paved apron around the building, at least 1 m wide and falling at least 1:50 away from the building, keeps surface water away from the footings.
  • Root management: Where roots of an existing tree affect footings, removing subsidiary roots or installing a vertical root barrier may help; drying of the soil may need engineering advice.
  • Structural Reinforcement: In high-risk areas, consider additional footing reinforcement to mitigate potential soil movement.

Following these guidelines reduces the risk of damage to buildings from tree roots and soil drying.

References

  • Standards Australia, AS 2870-2011 Residential slabs and footings, Appendix B, Clause B2.3.
  • CSIRO, Foundation Maintenance and Footing Performance (2024). research.csiro.au
Sketch of a house beside a tree, with the soil cut away to show the tree's roots spreading under the house.

Unsure how this applies to your property?

Our forensic structural engineers inspect homes in Victoria, Tasmania, Queensland, South Australia, New South Wales and the ACT.

Related service: Forensic Structural Investigation

Talk to an engineer

Engineering record

Standard

AS 2870-2011

Residential slabs and footings

Current edition, listed as Pending Revision by Standards Australia. Status checked November 2026.

Clauses discussed

Appendix B, Clause B2.3

Prepared by

Sara Khani

Senior Forensic Structural Engineer

Revision

Rev A

Published 22 November 2026

Insight ref.

AS2870-01

Quote it when you contact us about this page.

Scope

This page explains the Standard in general terms. It is not an assessment of any particular property.

Revision history

A, 22 November 2026: first issue.

More Building Code Insights

Other Australian Standards and NCC requirements, explained by our engineers.

  • Sketch of a brick wall on the edge of a concrete slab, with the soil cut away to show the footing beneath.
    AS 2870-2011

    Surface Drainage Requirements for Concrete Slabs

    Fall away from the building and slab height above ground under AS 2870-2011 and NCC Housing Provisions 3.3.3, with each state’s NCC edition.

    22 Nov 2026 · Reading time 4 minutes

  • Sketch of a tilted house dripping water into a spreading puddle.
    AS 2870-2011

    Abnormal Moisture Conditions

    Abnormal moisture conditions under AS 2870-2011, with examples before, during and after construction: trees, drainage, leaks and watering.

    22 Nov 2026 · Reading time 3 minutes

  • Sketch of a house outline with a gauge marked NCC inside, a tree, a downpipe, a stone path and a cut-away of the soil below.
    AS 2870-2011

    Normal Site

    How AS 2870-2011 defines a normal site: Class A, S, M, H1, H2 or E, moisture changes from climate, building, subdivision and normal gardens only.

    22 Nov 2026 · Reading time 2 minutes

View All Insights