Forensic and structural engineers servingServing VIC, TAS, QLD, SA, NSW and the ACT

AS 1720Timber structures

Allowable Deflection Limit for Posi-Strut Flooring

In brief

MFS applies a deflection limit of span/600 to Posi-Strut floors, stricter than the span/300 it generally uses for standard timber floor joists. On a 6 m span that is a maximum of 10 mm. Limits may vary slightly between manufacturers.

Sara Khani

Written by

Sara Khani

Senior Forensic Structural Engineer

Standard

AS 1720

Published

22 November 2026

Revision A · Reading time 1 minute

In Australian residential construction, floor joist deflection is a critical factor in ensuring structural integrity and occupant comfort.

Standard Timber Floor Joists

  • In MFS’s design practice, the maximum allowable deflection is generally span/300.
  • This means the floor can deflect up to 1/300th of its span length.

Specialist Floor Systems (e.g., Posi-Struts)

  • We apply a stricter limit of span/600. Limits may vary slightly between manufacturers.
  • This tighter tolerance ensures better performance for these engineered products.

MFS designs timber floors to AS 1720 Timber structures.

Practical Example

  • For a 6 m span using a specialist system:
    • Calculation: 6000 mm ÷ 600 = 10 mm
    • The maximum allowable deflection would be 10 mm.

Important Considerations

  • Deflection limits may vary based on:
    • Project-specific requirements
    • Occupancy type
    • The National Construction Code and state building regulations

Best Practice

  • Engineers should always consult the latest version of Australian standards when designing floor systems.
  • Manufacturer guidelines should be followed for specialised products.

References

  • Standards Australia, AS 1720 Timber structures.
Sketch of a heavy weight marked KG on a floor supported by open-web joists with timber chords and metal webs.

Unsure how this applies to your property?

Our forensic structural engineers inspect homes in Victoria, Tasmania, Queensland, South Australia, New South Wales and the ACT.

Related service: Preventative Structural Design Engineering

Talk to an engineer

Engineering record

Standard

AS 1720

Timber structures

Prepared by

Sara Khani

Senior Forensic Structural Engineer

Revision

Rev A

Published 22 November 2026

Insight ref.

AS1720-01

Quote it when you contact us about this page.

Scope

This page explains the Standard in general terms. It is not an assessment of any particular property.

Revision history

A, 22 November 2026: first issue.

More Building Code Insights

Other Australian Standards and NCC requirements, explained by our engineers.

  • Sketch of a house beside a tree, with the soil cut away to show the tree's roots spreading under the house.
    AS 2870-2011

    Tree Distance from Buildings

    Safe planting distances for trees near a house under AS 2870-2011, based on soil reactivity and the tree’s mature height.

    22 Nov 2026 · Reading time 2 minutes

  • Sketch of a brick wall on the edge of a concrete slab, with the soil cut away to show the footing beneath.
    AS 2870-2011

    Surface Drainage Requirements for Concrete Slabs

    Fall away from the building and slab height above ground under AS 2870-2011 and NCC Housing Provisions 3.3.3, with each state’s NCC edition.

    22 Nov 2026 · Reading time 4 minutes

  • Sketch of a tilted house dripping water into a spreading puddle.
    AS 2870-2011

    Abnormal Moisture Conditions

    Abnormal moisture conditions under AS 2870-2011, with examples before, during and after construction: trees, drainage, leaks and watering.

    22 Nov 2026 · Reading time 3 minutes

View All Insights