AS/NZS 2589:2017Gypsum linings: Application and finishing

Installation of Garage Ceilings

In brief

Conventional versus 1/3 fastener spacing for plasterboard ceilings under AS/NZS 2589, and why MFS applies 1/3 spacing to garage ceilings.

Sara Khani

Written by

Sara Khani

Senior Forensic Structural Engineer

Standard

AS/NZS 2589:2017

Current edition, status checked November 2026

Published

22 November 2026

Revision A · Reading time 2 minutes

The Australian Standard AS/NZS 2589 Gypsum linings – Application and finishing specifies different spacing requirements, conventional spacing and 1/3 spacing, for the installation of fasteners and adhesives in gypsum board ceilings based on specific needs and conditions.

Conventional Spacing is typically used under normal conditions where extra support is not crucial. It is generally adequate for standard residential buildings and internal areas without unusual load or significant environmental stressors. This standard spacing is sufficient in environments less affected by moisture, high winds, or structural movements, and where the ceiling does not support heavy fixtures or additional loads.

1/3 Spacing reduces the distance between fasteners and adhesives, thus increasing the number of fasteners used, providing greater support and stability. The 1/3 spacing is recommended for areas that may be subject to higher loads or where additional factors such as wind, vibration, moisture, or thermal expansion could impact the integrity of the ceiling.

Diagram of a plasterboard ceiling sheet across three ceiling joists, marking the screw or nail (F) and adhesive (A) points of the 1/3 method and the centreline (C).
Fastener (F) and adhesive (A) points for 1/3 spacing on a plasterboard ceiling. C marks the centreline. Drawing: MFS Engineering.

Unfortunately, this standard does not explicitly explain where the 1/3 spacing should be used. However, it clearly specifies that the installation of plasterboard linings must meet the requirements of Serviceability limit state. According to AS/NZS 2589 section 3.2.1: “Serviceability limit state – Consideration shall be made of the effects on installed gypsum linings resulting from self weight, humidity, imposed actions and internal and external environmental conditions. Notes: Sag in ceiling linings can occur over time as a result of self-weight, humidity, imposed actions and internal and external environmental conditions. Typical imposed actions include light fittings, fans, insulation and other services that might be fully or partially supported by the gypsum linings.”

Particularly for ceilings in garages, carports, verandahs, and alfresco areas, which are subject to more extreme conditions and loads, special attention is necessary for their fixing and detailing. Factors such as wind loads, condensation, roller door vibrations, and exposure to atmospheric variations (e.g., humidity, temperature) necessitate the use of 1/3 spacing.

Sketch of a garage with a sagging, wavy plasterboard ceiling as wind and leaves blow in through the open roller door.
A sagging plasterboard ceiling in a garage, exposed to wind through the open roller door. Illustration: MFS Engineering.

Therefore, in MFS’s view, ceilings in these areas should use the 1/3 spacing in Table 3 of AS/NZS 2589 to meet the serviceability limit state requirement of clause 3.2.1.

References

  • Standards Australia, AS/NZS 2589 Gypsum linings, clauses 3.2.1 and 7.6.3.6, Table 3.
  • Building Commission (WA), Industry Bulletin 085, Plasterboard ceiling failures (updated May 2017). wa.gov.au
Sketch of a garage with its plasterboard ceiling collapsed, the ceiling framing exposed and debris around a parked car.

Unsure how this applies to your property?

Our forensic structural engineers inspect homes in Victoria, Tasmania, Queensland, South Australia, New South Wales and the ACT.

Related service: Building Defects Inspection

Talk to an engineer

Engineering record

Standard

AS/NZS 2589:2017

Gypsum linings: Application and finishing

Current edition. Status checked November 2026.

Clauses discussed

Clause 3.2.1, Clause 7.6.3.6 and Table 3

Prepared by

Sara Khani

Senior Forensic Structural Engineer

Revision

Rev A

Published 22 November 2026

Insight ref.

AS2589-01

Quote it when you contact us about this page.

Scope

This page explains the Standard in general terms. It is not an assessment of any particular property.

Revision history

A, 22 November 2026: first issue.

More Building Code Insights

Other Australian Standards and NCC requirements, explained by our engineers.

  • Sketch of a house beside a tree, with the soil cut away to show the tree's roots spreading under the house.
    AS 2870-2011

    Tree Distance from Buildings

    Safe planting distances for trees near a house under AS 2870-2011, based on soil reactivity and the tree’s mature height.

    22 Nov 2026 · Reading time 2 minutes

  • Sketch of a brick wall on the edge of a concrete slab, with the soil cut away to show the footing beneath.
    AS 2870-2011

    Surface Drainage Requirements for Concrete Slabs

    Fall away from the building and slab height above ground under AS 2870-2011 and NCC Housing Provisions 3.3.3, with each state’s NCC edition.

    22 Nov 2026 · Reading time 4 minutes

  • Sketch of a tilted house dripping water into a spreading puddle.
    AS 2870-2011

    Abnormal Moisture Conditions

    Abnormal moisture conditions under AS 2870-2011, with examples before, during and after construction: trees, drainage, leaks and watering.

    22 Nov 2026 · Reading time 3 minutes

View All Insights